Click for larger image and other views

How can we improve our images or Product Specifications?

Mettler Toledo Infrared Moisture Analyzer, 0.01 Percent Moisture Content Readability

Be the first to review this item

ASIN B003P9WOUW

Specifications for this item
Number of Items
1
Overall Height
150  millimeters
Overall Width
230  millimeters
Cap Type
weight
Part Number
MJ33
Temperature Range
50/160  Degrees Celsius
Size Name
0.01 Percent Moisture Content Readability
Brand Name
Mettler Toledo
Maximum Temperature
160  Degrees Celsius
Upper Temperature Range
160  Degrees Celsius
Temperature Accuracy
1  Degrees Celsius
Capacity
35  grams
UNSPSC Code
41111513
Display
LCD back lit
Overall Length
360  millimeters

This item is no longer available

This item ships for FREE with 2-Day Shipping on orders over $50. (Details)

Want it delivered on Fri, Oct 31? Order in-stock items in the next 5 hrs 19 mins and choose One-Day Shipping at checkout.

  • Share

This item has already been added to

Update Quantity Cancel

Select a List Create New List


You can add a description later

Key Features

  • Moisture analyzer with 35g capacity and 0.01 percent moisture content accuracy (also called readability)
  • Backlit matrix display projects clear moisture readings
  • 80 reusable sample pans are included, and fit in the stainless steel, corrosion-resistant sample chamber
  • Two infrared heating elements help ensure quick, reliable results
  • RS232 port connects to a printer or computer, enabling compliance with industry practices and standards

Package Details

Shipping Weight: 15 pounds
Package Size: 21 x 16 x 14 inches

Product Description

The Mettler Toledo infrared moisture analyzer has a capacity of 35g, moisture content accuracy (also called readability) of 0.01 percent, and mass accuracy of 1mg. The matrix display is backlit to ensure easy readings of moisture content. Included are 80 aluminum sample pans that are 90mm in diameter and can be reused, but are also easily disposed of as needed, and help keep the sample chamber clear from spills. The sample pans fit in the stainless steel sample chamber, which resists corrosion from accidental spills from wet samples, and includes a draft shield and a heat shield to protect sample materials from air disturbances and direct heat. Two infrared heat sources dry samples. The RS232 port is positioned to connect to a printer or computer, and built-in functions enable work in compliance with good laboratory practices (GLP), good manufacturing practices (GMP), and International Organization for Standardization (ISO) standards.

The moisture analyzer displays four results: moisture content, dry content, weight, and ATRO moisture content, which is a measurement of moisture content as compared to dry weight. Two switch-off modes control when the analyzer ends the drying process. Automatic switch-off mode turns off the heating elements based on weight loss per unit of time, and timed switch-off mode turns off the heating elements after a user-configured period of time. The ABS plastic and die-cast metal housing protect the internal weighing cell from environmental influences and impact. The analyzer has non-slip, adjustable feet and an integrated spirit level to ensure a stable, level surface.

Specifications

Capacity range 0.5 to 35g
Moisture content readability 0.01 percent
Mass readability 1mg
Repeatability (sd) 0.15 percent (2g sample); 0.05 percent (10g sample)
Operating temperature range 50 to 160 degrees C
Drying time range 1 to 99 minutes
Weight of moisture analyzer 4.3kg
Units of measurement Moisture content (MC), dry content (DC), weight in grams (g), ATRO moisture content (AM)
Power requirement 100-120V AC / 220-240V AC, 50-60 Hz
Sample pan, diameter 90mm
Balance dimensions with draft shield, H x W x D 23 x 15 x 36cm

H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.

Balances are measuring instruments used to determine the mass of an object, while scales are used to measure the weight of an object. The measurement results from balances are generally considered to be more precise compared to results from scales. Mechanical balances are the simplest type of balance, and use a lever and slide to indicate the measurement. Conventional balances are commonly used in offices, the jewelry industry, and in kitchens, and display results digitally, but are less precise than analytical balances. Analytical balances measure to a high degree of precision and accuracy (0.0001 g or better), and display results digitally. These balances have a cover with doors to prevent dust and airflow from affecting the measurement. Moisture balances analyze moisture content in a material sample, using infrared or halogen heat sources to dry the sample and then calculate the moisture content from the before- and after-drying weight, and display results digitally, on the balance, or transfer the information for display on a computer.

Mettler-Toledo manufactures precision instruments for use in research, scientific, and quality control labs for the pharmaceutical, chemical, food, and cosmetics industries. This company, founded in 1989, is headquartered in Switzerland.

What’s in the Box?

  • Mettler Toledo MJ33 infrared moisture analyzer
  • 80 aluminum sample pans
  • Pan handler
  • Draft shield
  • Power cord
  • Instructions

How can we improve our Product Description?

Customer Reviews

There are no customer reviews yet.

Be the first to review this item

Go to the HomePage

Order by Phone
M-F 8am-8pm ET, Sat-Sun 8am-5pm ET 800-220-4242

My Account| Returns| Help

Website Feedback| Contact Us| Sell on AmazonSupply| Become an Affiliate

Privacy Notice| Conditions of Use

Follow Us 

© 2014 Amazon.com, Inc. and its affiliates.