Click for larger image and other views

How can we improve our images or Product Specifications?

Hanna Instruments HI935005 K-Type Waterproof Thermocouple Thermometer, -50 to 1350 Degrees C; -58 to 2462 Degrees F, Accuracy of + or - 0.2% of Full Scale

Be the first to review this item

ASIN B0085XCSX6

Specifications for this item
Number of Items
1
Measurement Type
Temperature
Part Number
HI935005
Brand Name
Hanna Instruments
UNSPSC Code
41000000

This item is no longer available

This item ships for FREE with 2-Day Shipping on orders over $50. (Details)

Want it delivered on Fri, Aug 29? Order in-stock items in the next 18 hrs 10 mins and choose One-Day Shipping at checkout.

  • Share

This item has already been added to

Update Quantity Cancel

Select a List Create New List


You can add a description later

Key Features

  • Digital thermometer for applications requiring a broad range of temperature measurements, including furnaces, kilns, freezers, and other industrial applications
  • Measures temperature from -50 to 1350 degrees C (-58 to 2462 degrees F), with an accuracy of + or - 0.2% of full scale
  • K-type thermocouple sensor has a broader temperature measurement range than a thermistor sensor
  • Displays current temperature and highest or lowest temperature reading for the session
  • Displays readings in degrees Fahrenheit or Celsius

Package Details

Shipping Weight: 1.15 pounds
Package Size: 7.5 x 5 x 2.7 inches

Product Description

The Hanna Instruments HI935005 K-type thermocouple digital thermometer is for use in applications requiring a broad range of temperature measurements, including furnaces, kilns, freezers, and other industrial applications. It measures temperature from -50 to 1350 degrees C (-58 to 2462 degrees F), with an accuracy of + or - 0.2% of full scale. The K-type thermocouple sensor has a broader temperature measurement range than a thermistor sensor but provides lower accuracy. The LCD screen shows the current temperature and the highest or lowest temperature reading for the session. The operator can choose to display readings in degrees Fahrenheit or Celsius. The hold function keeps a measurement on the display so it can be recorded. A K-type thermocouple probe (not included) can be connected to the input port for taking measurements. The thermometer operates on three AA batteries (included). To conserve battery life, the user can program the thermometer to automatically turn off after either 8 or 60 minutes of non-use. The display shows current battery charge at start-up, and a low-battery indicator alerts the operator and turns off the thermometer when low battery charge might affect the accuracy of readings. A waterproof casing helps protect against damage from splashes and spills.

Specifications

Temperature measurement range-50 to 1350 degrees C (-58 to 2462 degrees F)
Resolution0.1 degree C, up to 199.9 degrees C; 1 degree C, outside (0.1 degree F, up to 399.9 degrees F; 1 degree F, outside)
Accuracy+ or - 0.2% of full scale
Typical electromagnetic compatibility (EMC) deviation, with HI 766 probes (not included)+ or - 3 degrees C (+ or - 6 degrees F)
Operating environment temperature and humidity-10 to 50 degrees C (14 to 122 degrees F); 100% maximum relative humidity
Power supply1.5V AA batteries (three, included)
Weight253 g (8.3 oz.)
Dimensions*150 x 80 x 36 mm/5.9 x 3.1 x 1.4 in. (H x W x D)

*H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.

Digital thermocouple thermometers measure the temperature of air, liquids, or surfaces. They may measure temperature in Celsius, Fahrenheit, or both. Thermocouple thermometers are composed of two conductors of different metals, usually alloys of the same metal, which touch at the sensor end of the thermometer. The difference in conductivity between the two metal pieces produces a voltage flow between the sensor end and the open end of each conductor, which can be used to determine the temperature. Different alloys are used for different temperature ranges. Thermocouple thermometers are used in applications that require a large temperature range and do not require a high degree of accuracy. These thermometers are used in kilns, turbine exhaust systems, and furnaces.

Hanna Instruments manufactures analytical instrumentation and supplies, including pH meters, electrodes, chemical reagents, and buffer solutions. The company, founded in 1978 and headquartered in Woonsocket, RI, meets International Organization for Standardization (ISO) 9001 standards.

What's in the Box?
  • Hanna Instruments HI935005 K-type thermocouple digital thermometer
  • (3) AA batteries
  • Instructions

How can we improve our Product Description?

Customer Reviews

There are no customer reviews yet.

Be the first to review this item

Go to the HomePage

Order by Phone
M-F 8am-8pm ET, Sat-Sun 8am-5pm ET 800-220-4242

My Account| Returns| Help

Website Feedback| Contact Us| Sell on AmazonSupply| Become an Affiliate

Privacy Notice| Conditions of Use

Follow Us 

© 2014 Amazon.com, Inc. and its affiliates.